{"product_id":"ccv-icv-solution-1-500ml","title":"CCV\/ICV SOLUTION #1, 500mL","description":"\u003ch4 style=\"vertical-align: middle; display: inline;\"\u003eDescription\/ Intended use\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eICV\u003c\/strong\u003e (Initial Calibration Verification) Checks the calibration against a second calibration source. To be run after each calibration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCCV\u003c\/strong\u003e (Continuing Calibration Verification) A continuing periodic check on accuracy and drift. To be run after each calibration and every 10 samples.\u003c\/p\u003e\n\u003cbutton class=\"accordion\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0296\/2155\/1241\/files\/information-btn.png?v=1588344634\" width=\"16px\" height=\"16px\"\u003e \u003cstrong\u003eRead more...\u003c\/strong\u003e\u003c\/button\u003e\n\u003cdiv class=\"panel\"\u003e\n\u003cp\u003e\u003cstrong\u003eICV\u003c\/strong\u003e demonstrates that the instrument is capable of acceptable performance at the beginning of the analytical run.\n1) Immediately after each system has been calibrated, the accuracy of the initial calibration must be verified and documented for each target analyte by the analysis of an ICV solution(s). If the ICV %R falls outside of the control limits, the analysis should be terminated, the problem corrected, the instrument recalibrated, and all affected samples reanalysed. \n 2) If the ICV solution is not available from USEPA, or where a certified solution of an analyte is not available from any source, analyses shall be conducted on an independent standard at a concentration level other than that used for instrument calibration (or the CRI), but within the calibrated range. \n 3) The ICV solution shall be run at each analytical wavelength used for analysis.\u003c\/p\u003e\n\u003cdiv class=\"ivdspacer\"\u003e \u003c\/div\u003e\n\u003cstrong\u003eCCV\u003c\/strong\u003e demonstrates that the initial calibration is still valid by checking the performance of the instrument on a continuing basis. \n1) To ensure accuracy during the course of each analytical run, the CCV shall be analysed and reported for each wavelength used for the analysis of each analyte. \n2) The CCV standard shall be analysed at a frequency of 10% or every two hours during an analytical run, whichever is more frequent. The CCV standard shall also be analysed at the beginning of the run, and again after the last analytical sample. \n3) The analyte concentration(s) in the CCV standard(s) shall be different than the concentration used for the ICV, and shall be one of the following solutions at, or near, the mid-range levels of the calibration curve:  \nA. USEPA solutions. \n B. National Institute of Standards and Technology (NIST) standards; or \n C. A Laboratory-prepared standard solution (self-prepared or commercially available). \n4) The same CCV standard solution shall be used throughout the analysis runs for a Sample Delivery Group (SDG). \n5) The CCV shall be analysed in the same fashion as an actual sample. Operations such as the number of replicate analyses, the number and duration of the instrument rinses etc., affect the measured CCV result and are not to be applied to the CCV to an extent greater than was applied to the associated analytical samples. If the %R of the CCV  was outside of the control limits, the analysis should be terminated, the problem corrected, the instrument recalibrated, and the preceding 10 analytical samples or all analytical samples analysed since the last compliant calibration verification reanalysed.\n\u003c\/div\u003e\n\n\n\n\u003c!---------------IMPORTANT-ADD THIS SECTION TO THE END OF THE HTML-------------\u003e\n\u003cscript\u003e\/\/ \u003c![CDATA[\nvar acc = document.getElementsByClassName(\"accordion\");\nvar i;\n\nfor (i = 0; i \u003c acc.length; i++) {\n  acc[i].addEventListener(\"click\", function() {\n    this.classList.toggle(\"active\");\n    var panel = this.nextElementSibling;\n    if (panel.style.display === \"block\") {\n      panel.style.display = \"none\";\n    } else {\n      panel.style.display = \"block\";\n    }\n  });\n}\n\/\/ ]]\u003e\u003c\/script\u003e\n\u003ch4 style=\"vertical-align: middle; display: inline;\"\u003eProduct Specifications\u003c\/h4\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0296\/2155\/1241\/files\/ico_hazardous.gif\" width=\"40\" height=\"40\" alt=\"\" style=\"vertical-align: middle; display: inline;\"\u003e \u003c!-----Product Details-----\u003e\n\u003cdiv class=\"specific clearfix\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv class=\"specific_in_lft\"\u003e\n\u003ch4\u003ePart #:\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specific_in_rgt\"\u003e\n\u003cp\u003eQCP-CICV-1-500ML\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv class=\"specific_in_lft\"\u003e\n\u003ch4\u003eDescription:\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specific_in_rgt\"\u003e\n\u003cp\u003eCCV\/ICV SOLUTION #1, 500mL\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv class=\"specific_in_lft\"\u003e\n\u003ch4\u003eMatrix:\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specific_in_rgt\"\u003e\n\u003cp\u003e7% v\/v Nitric Acid\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv class=\"specific_in_lft\"\u003e\n\u003ch4\u003eDilution:\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"specific_in_rgt\"\u003e\n\u003cp\u003e1:100 or 1:500\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"specific_rgt\"\u003e\n\u003cdiv style=\"width: 340px; height: 170px; padding: 0 0 0 10px;\"\u003e\n\u003cdiv style=\"float: left; clear: right;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0296\/2155\/1241\/files\/tct-inorganic-ventures.jpg?v=1582128137\" width=\"150\" height=\"170\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"float: left; padding: 5px 10px 10px 10px; background-color: #24a5d9; width: 170px; height: 170px; text-align: justify; text-justify: inter-word; border-radius: 10px;\"\u003e\n\u003cp style=\"text-align: left; color: #ffffff; line-height: 22px;\"\u003eEvery Inorganic Ventures CRM is sold in patented \u003cstrong\u003eTCT\u003c\/strong\u003e packaging giving your product up to 3 years shelf life. \u003ca href=\"https:\/\/esslabshop.com\/pages\/tct-splash\" style=\"color: #ffffff;\"\u003e\u003cstrong\u003eRead more\u003c\/strong\u003e\u003c\/a\u003e...\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"height: 10px; clear: left;\"\u003e \u003c\/div\u003e\n\u003c!----------------------Product Specifications end-------------------------\u003e \u003c!-----------------------ANALYTE START-------------------------------------\u003e\n\u003cdiv class=\"analytes\"\u003e\n\u003cul class=\"columned\"\u003e\n\u003cli class=\"heading\"\u003e\n\u003cul\u003e\n\u003cli\u003eAnalyte\u003c\/li\u003e\n\u003cli\u003eµg\/mL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli class=\"heading hidden-xs\"\u003e\n\u003cul\u003e\n\u003cli\u003eAnalyte\u003c\/li\u003e\n\u003cli\u003eµg\/mL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eAl\u003c\/li\u003e\n\u003cli\u003e1000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eBa\u003c\/li\u003e\n\u003cli\u003e1000\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eBe\u003c\/li\u003e\n\u003cli\u003e25\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eCa\u003c\/li\u003e\n\u003cli\u003e2500\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eCr\u003c\/li\u003e\n\u003cli\u003e100\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eCo\u003c\/li\u003e\n\u003cli\u003e250\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eCu\u003c\/li\u003e\n\u003cli\u003e125\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eFe\u003c\/li\u003e\n\u003cli\u003e500\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eMg\u003c\/li\u003e\n\u003cli\u003e2500\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eMn\u003c\/li\u003e\n\u003cli\u003e250\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eNi\u003c\/li\u003e\n\u003cli\u003e250\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eK\u003c\/li\u003e\n\u003cli\u003e2500\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eAg\u003c\/li\u003e\n\u003cli\u003e125\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eNa\u003c\/li\u003e\n\u003cli\u003e2500\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eV\u003c\/li\u003e\n\u003cli\u003e250\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eZn\u003c\/li\u003e\n\u003cli\u003e250\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"height: 10px; clear: left;\"\u003e \u003c\/div\u003e\n\u003c!--------------------------------------------------Analyte end---------------------------------------------------\u003e \u003c!-----------------------------------------------DOCUMENT GOES HERE-----------------------------------------------\u003e\n\u003cdiv class=\"associate document\"\u003eDocumentation:\n\u003cul\u003e\n\u003cli\u003e\u003ca class=\"pdf\" target=\"_blank\" href=\"https:\/\/www.inorganicventures.com\/coa\/Letterhead\/IV\/QCP-CICV-1_P2-MEB685884.pdf\" rel=\"noopener noreferrer\"\u003eTCT Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"pdf\" href=\"http:\/\/ivlabsmsds.thewercs.com\/external\/private\/results.aspx?language=d__EN\u0026amp;subformat=d__AGHS\u0026amp;productName=QCP-CICV-1\" target=\"_pdf\"\u003eOSHA SDS\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca class=\"pdf\" href=\"http:\/\/ivlabsmsds.thewercs.com\/external\/private\/results.aspx?language=d__EN\u0026amp;subformat=d__EGHS\u0026amp;productName=QCP-CICV-1\" target=\"_pdf\"\u003eEU SDS\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"height: 10px; clear: left;\"\u003e \u003c\/div\u003e\n\u003c!--------------------------------------------------Resources--------==-------------------------------------------\u003e \u003c!------Associated Certifications-----\u003e\n\u003cp\u003eAssociated Certifications: \u003ca href=\"https:\/\/esslabshop.com\/pages\/inorganic-ventures-cross-reference-guide\"\u003eISO 17034\u003c\/a\u003e | \u003ca href=\"https:\/\/www.inorganicventures.com\/iso-accreditations\/\"\u003eISO 17025\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv style=\"height: 10px; clear: left;\"\u003e \u003c\/div\u003e\n\u003c!-----------------------------------------------IV tick-boxes-----------------------------------------------\u003e\n\u003cp\u003e\u003cstrong\u003eOnly Inorganic Ventures can give you ALL of these.....\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"float: left; display: inline; padding: 10 0 0 0;\"\u003e\n\u003cspan style=\"color: green;\"\u003e✔\u003c\/span\u003e Traceable to NIST SRMs\u003cbr\u003e \u003cspan style=\"color: green;\"\u003e✔\u003c\/span\u003e Produced under ISO 17025\u003cbr\u003e \u003cspan style=\"color: green;\"\u003e✔\u003c\/span\u003e Produced under ISO 17034\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"float: left; display: inline; padding-left: 30px;\"\u003e\n\u003cspan style=\"color: green;\"\u003e✔\u003c\/span\u003e Assayed by validated wet chemical procedures\u003cbr\u003e \u003cspan style=\"color: green;\"\u003e✔\u003c\/span\u003e Assayed by validated ICP-OES procedures\u003cbr\u003e \u003cspan style=\"color: green;\"\u003e✔\u003c\/span\u003e Trace metallic impurities determined by ICP and ICP-MS\u003c\/div\u003e\n\u003cp style=\"clear: left; padding: 0 0 0 0;\"\u003e\u003cstrong\u003eAnd up to 3 YEARS SHELF LIFE with \u003ca href=\"https:\/\/esslabshop.com\/pages\/tct-splash\"\u003eTCT packaging\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Inorganic Ventures","offers":[{"title":"Default Title","offer_id":31714557689993,"sku":"QCP-CICV-1-500ML","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0296\/2155\/1241\/products\/iv_product_placeholder_76902dfa-e76f-4bcb-928a-3091cc6797a3.png?v=1734613985","url":"https:\/\/esslabshop.com\/products\/ccv-icv-solution-1-500ml","provider":"ESSLAB","version":"1.0","type":"link"}