Initial Calibration Verification Standard 1A in 5% HNO3/tr. Tartaric Acid/tr. HF, 500 mL

Please Login or Register to see price.
Shipping calculated at checkout.
SKU: ICV-1A

Initial Calibration Verification Standard 1A in 5% HNO3/tr. Tartaric Acid/tr. HF, 500 mL

  • Part No:

    Volume:

    Storage Conditions:

    SDS:

    ICV-1A

    500 mL

    Ambient

    Safety Data Sheet

    Matrix:

    Units/Pack:

    Shipping Info:

    Expiration (Months):

    5% HNO3/tr. Tartaric Acid/tr. HF

    1

    12

  • CLP Standards for ICP & ICP-MS

    Our Contract Laboratory Program (CLP) standards allow you to Calibrate with Confidence®. The standards are to be used in conjunction with the Statement of Work for Inorganic Analysis; Multi-Media/Multi-Concentration Document Number ILM 05.3/ISM 01.2.

    The final ICP check, performed in our own laboratories, is your stamp of assurance. We calibrate our instruments with traceable reference materials and show you the actual found value of the solution you receive, not just an ideal, calculated number as so many other standards manufacturers do. The combination of elements, concentrations and matrices listed have been diagnosed by SPEX CertiPrep for convenience of use and stability.

    US EPA SOW ILM 05.3/ISM 01.2 gives specific procedures for the methods of analysis, target elements, and concentrationlevels. Standards are specified not only by the elements present and their relative concentrations, but also the order and frequency of running standards, blanks and samples. Details of these specifications may be found in the US EPA SOW ILM 05.3/ISM 01.2 in the following sections:

    • Exhibit C, Inorganic Target Analyte List (TAL)

    • Exhibit D, Analytical Methods

    • Exhibit E, QA/QC Requirements

    Initial Calibration Verification for CLP Methods

    The US EPA retains analytical services through the Contract Laboratory Program (CLP). The CLP follows detailed SOPs derived from EPA methods. The CLP methods require calibration of analytical instrumentation whithin the expected quantitative range (ICAL standards) and additional CLP QA standards (ICV standards) to verify the calibration curve at each of the selected wavelengths that wil be used for sample analysis.

    Our verification standards contain all of the elements on the TAL list and are independent standards for testing an instruments calibration curve. SPEX CertiPrep's ICV standards are designed to be used with their corresponding instrument calibration standards (ICAL).

    We recommend dilution of ICV standards to a range within your instruments calibration curve. A dilution of 20-fold is recommended.

  • Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Component:

    Calcium

    Magnesium

    Potassium

    Sodium

    Aluminum

    Barium

    Iron

    Antimony

    Cobalt

    Vanadium

    Nickel

    Copper

    Zinc

    Manganese

    Arsenic

    Chromium

    Silver

    Thallium

    Beryllium

    Cadmium

    Selenium

    Lead

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    Concentration:

    5,000 µg/mL

    5,000 µg/mL

    5,000 µg/mL

    5,000 µg/mL

    200 µg/mL

    200 µg/mL

    100 µg/mL

    60 µg/mL

    50 µg/mL

    50 µg/mL

    40 µg/mL

    25 µg/mL

    20 µg/mL

    15 µg/mL

    10 µg/mL

    10 µg/mL

    10 µg/mL

    10 µg/mL

    5 µg/mL

    5 µg/mL

    5 µg/mL

    3 µg/mL