Hamilton ML-600 Dual Syringe Dispenser
£9,576.47
Hamilton ML-600 Dual Syringe Diluter
£6,874.29
Hamilton 1710BFP 100ul Syringe
£167.06
1002 LLSN (20/4.38"/3)
£167.06
1002 LLSN (18/8.5"/3)
£160.00
1710 C 100uL SPCL
£117.76
PURGE & TRAP VALVE
£196.47
Inert Gas Sampling Valve
£155.29
Female Luer Cap
£11.76
1750 RN 500uL Syr Terasaki
£1,187.06
1725 RN 250uL Syr Terasaki
£1,209.41
1710 RN 100uL Syr Terasaki
£1,187.06
1705 RN 50uL Syr Terasaki
£1,187.06
1702 RN 25uL Syr Terasaki
£1,058.82
Hamilton Priming Kit
£228.00
- Login Account
- 0
- 0
-
0 Your Cart £0.00
Hamilton ML-600 Dual Syringe Dispenser
£9,576.47
Hamilton ML-600 Dual Syringe Diluter
£6,874.29
Hamilton 1710BFP 100ul Syringe
£167.06
1002 LLSN (20/4.38"/3)
£167.06
1002 LLSN (18/8.5"/3)
£160.00
1710 C 100uL SPCL
£117.76
PURGE & TRAP VALVE
£196.47
Inert Gas Sampling Valve
£155.29
Female Luer Cap
£11.76
1750 RN 500uL Syr Terasaki
£1,187.06
1725 RN 250uL Syr Terasaki
£1,209.41
1710 RN 100uL Syr Terasaki
£1,187.06
1705 RN 50uL Syr Terasaki
£1,187.06
1702 RN 25uL Syr Terasaki
£1,058.82
Hamilton Priming Kit
£228.00
Split/splitless injection consists of a heated chamber with a glass liner into which the sample is injected through the septum. A microsyringe is used to inject the sample through a rubber septum into a flash vaporizer chamber at the head of the column. The sample vaporizes to form a mixture of carrier gas, vaporized solvent and vaporized analytes. In the split mode, only a proportion of this mixture reaches the column but most exits through the split outlet. This avoids overloading the column. In the splitless mode, the split vent is closed so that the vaporized analyte passes onto the column. This mode is more sensitive and adequate for trace analysis.
Volume | 50 µL |
---|---|
Syringe Type | Gastight |
Syringe Series | 1700 |
Termination | Cemented Needle (N) |
Needle | Cemented Needle |
Gauge | 22s gauge |
Point Style | 2 |
Needle Length | 2 inch (51 mm) |
Fluid Path | SST, borosilicate glass, PTFE |
Autoclavable | No |
Gas Sterilizable | Yes |
Pressure | 1000 psig (68.9 bar) |
Maximum Temperature | 50°C / 122°F |
Minimum Temperature | 10°C / 50°F |
Barrel Inner Diameter | 0.041 inches (1.03 mm) |
Barrel Outer Diameter | 0.305 inches (7.75 mm) |
Needle Inner Diameter | 0.0059 inches (0.15 mm) |
Needle Outer Diameter | 0.0283 inches (0.72 mm) |
Std Needle Dead Volume | 1.13 µL |
Sales Quantity | 1 syringe per pack |
Related Products
Recently viewed products
Shopping cart
close
-
WHAT ARE YOU LOOKING FOR?Search
- Login / Register
- Reference Materials
- Liquid Handling
- Chromatography and Spectroscopy
- Testing
- Labware
- Resources
- Wishlist (0)
- Compare (0)
- Contact Us