ML600 Basic user manual
£50.59
Hamilton 1725BFP 250 µL Syringe
£124.76
ML600 Universal Valve Plug
£23.53
Hamilton ML-600 Dual Syringe Diluter
£6,874.29
Hamilton Cross Tube Assembly
£43.53
Hamilton 1705BFP 50ul Syringe
£167.06
Hamilton 1710BFP 100ul Syringe
£167.06
Hamilton 250 µL, LT Syringe
£109.00
Hamilton 1725 LT 250µL
£79.00
Hamilton 1010 TLL 10mL Syringe
£101.00
Hamilton Valve HV 3-2-Y
£414.80
Hamilton ML-600 Diluter Assy.
£2,569.41
Hamilton ML600/ML700 Base Plate
£106.66
Hamilton ML-700 Dispenser | ML725-DIS
£7,319.05
Tubing Retention Clips
£67.06
Microlab Cable Management System
£172.94
Hamilton ML600 1mL SAL Syringe
£196.47
Hamilton ML-600 Dual Syringe Dispenser
£9,576.47
Hamilton 1702BFP 25ul Syringe
£124.76
Hamilton 1750BFP 500 µL Syringe
£124.76
- Login Account
- 0
- 0
-
0 Your Cart £0.00
ML600 Basic user manual
£50.59
Hamilton 1725BFP 250 µL Syringe
£124.76
ML600 Universal Valve Plug
£23.53
Hamilton ML-600 Dual Syringe Diluter
£6,874.29
Hamilton Cross Tube Assembly
£43.53
Hamilton 1705BFP 50ul Syringe
£167.06
Hamilton 1710BFP 100ul Syringe
£167.06
Hamilton 250 µL, LT Syringe
£109.00
Hamilton 1725 LT 250µL
£79.00
Hamilton 1010 TLL 10mL Syringe
£101.00
Hamilton Valve HV 3-2-Y
£414.80
Hamilton ML-600 Diluter Assy.
£2,569.41
Hamilton ML600/ML700 Base Plate
£106.66
Hamilton ML-700 Dispenser | ML725-DIS
£7,319.05
Tubing Retention Clips
£67.06
Microlab Cable Management System
£172.94
Hamilton ML600 1mL SAL Syringe
£196.47
Hamilton ML-600 Dual Syringe Dispenser
£9,576.47
Hamilton 1702BFP 25ul Syringe
£124.76
Hamilton 1750BFP 500 µL Syringe
£124.76
- Home
- Hamilton Education
- Hamilton 10 µL, Small Removable NDL, 0.17 mm, 10 cm, point style 3
On-column injection employs the direct introduction of the liquid sample into the column. This is very useful for the analysis of thermally unstable samples and avoids boiling point discrimination. On-column injection requires special syringes with the following features:
- Small outer diameter needles adjusted to the inner diameter of the column (0.17 mm needle for columns with 0.25 mm inner diameter, 32 gauge for columns with 0.25 mm inner diameter and 26 gauge for columns with a 0.53 mm inner diameter)
- Longer needles tailored to pass through the injector and reach within the capillary column
- Point style 2 adapted to the typical septum of the on-column injector
- Small volumes of 5 or 10 µL
Volume | 10 µL |
---|---|
Syringe Type | Gastight |
Syringe Series | 1700 |
Termination | Removable Needle (RN) |
Needle | Small RN |
Gauge | 0.17 mm |
Point Style | 3 |
Needle Length | 3.94 inch (100 mm) |
Fluid Path | PTFE, boroscilicate glass, fused silica |
Autoclavable | Yes |
Gas Sterilizable | Yes |
Pressure | 1000 psig (68.9 bar) |
Maximum Temperature | 115°C / 239°F |
Minimum Temperature | 10°C / 50°F |
Barrel Inner Diameter | 0.018 inches (0.460 mm) |
Barrel Outer Diameter | 0.260 inches (6.60 mm) |
Needle Inner Diameter | 0.00394 inches (0.10 mm) |
Needle Outer Diameter | 0.00669 inches (0.17 mm) |
Std Needle Dead Volume | 0.91 µL |
Sales Quantity | 1 syringe per pack |
Related Products
Recently viewed products
Shopping cart
close
-
WHAT ARE YOU LOOKING FOR?Search
- Login / Register
- Reference Materials
- Liquid Handling
- Chromatography and Spectroscopy
- Testing
- Labware
- Resources
- Wishlist (0)
- Compare (0)
- Contact Us